What is MONMSG in as400?
What is MONMSG in as400?
MONMSG Introduction-Go4As400.com. The monitor message (MONMSG) command monitors for the escape/status/notification messages that exist in a program at run time and allows us to take the corrective action for those messages. The messages are sent to the program message queue for the conditions specified in the command.
What is the command to check the object in as400?
The Check Object (CHKOBJ) command checks object existence and verifies the user’s authority for the object before trying to access it. If the object exists and the user has the proper authority for the object, no error messages are sent to the user.
Which is a type of Monmsg in CL?
The MONMSG command can be coded following most commands in a CL program or ILE CL procedure. A MONMSG command that is not placed at the beginning of the program applies only to the immediately preceding command; this is called a command-level MONMSG command.
What is library list in AS400?
The library list on the AS/400 is similar to the “path” on PC’s. Mainframe programmers may compare it to the “steplib” or “joblib”. It defines the order of libraries that the operating system uses to find objects. When you execute a command or call a program, the AS/400 must know where to find the command or program.
Can Monmsg command be the first command in a CL program?
What is Opnid in AS400?
Ü OPNID in DCLF. · Open id is an identifier for any opened file in the CL program.
What is open data path in AS400?
An open data path is the path through which all input and output operations for a file are performed. Usually a separate open data path is defined each time a file is opened.
How many libraries can be there in library list AS400?
250 library names
The same is true of the AS/400 and it uses an object called the library list ( *LIBL ). This object doesn’t exist on its own and is always associated with another object like a job or a job description ( *JOBD ). As of OS/400 V5R1 the user portion of the Library List can contain up to 250 library names.
What is current library in AS400?
The current library (*CURLIB) is the first user library that is searched before the rest of the user libraries in the list… The current library (*CURLIB) is the first user library that is searched before the rest of the user libraries in the list when the system looks for an object.
How do I find the source of an object in AS400?
To see all the source members of a source physical file, the command used is WRKMBRPDM. To add source of any type of object in a source physical file we use the command WRKMBRPDM and then F6.
What are the types of access path in as400?
Aceess Path & Types of Access Path-Go4As400.com. Access path describes the order in which records are to be read. Access paths can be kept on the system permanently (such as physical or logical file) or temporarily. OPNQRYF command may create a temporary access path for use one time, and then discard the access path.
What is open data path?
How are objects stored in AS400?
Certain types of the AS/400 object (database file, storage areas and executable program objects) can be compiled, copied, and stored into/from many different libraries concurrently, with the Library List hierarchy determining which instance of the object to use during execution of any application that utilizes that …
What are chkobj and monmsg used for?
These two commands (CHKOBJ and MONMSG) are used to verify that you have both add (*ADD) and delete (*DLT) authorities for logical file FILEA and each of the physical file members on which the logical file member MBR1 in the logical file FILEA is based.
What is the chkobj command?
The Check Object (CHKOBJ) command checks object existence and verifies the user’s authority for the object before trying to access it. If the object exists and the user has the proper authority for the object, no error messages are sent to the user. For verification, as many as ten specific authorities can be specified on the command.
How does the monmsg command monitor messages sent by previous commands?
The command-level MONMSG command monitors only messages sent by the previous command. If the message sent by that command meets the conditions specified in the MONMSG command, the action specified in the same MONMSG command is taken.
What is a program level monmsg command?
If one or more MONMSG commands are placed at the beginning of the program, immediately following the declare commands or the PGM command if there are no declare commands, they monitor messages sent by all of the commands in the program (maximum of 100). This is called a program-level MONMSG command.